ACCU-CAL™ 50V Visible Radiometer

for use with Visible Light Curing Systems  CE Marked - Available Globally


Consistent curing requires periodic monitoring of visible energy intensity or dose. The ACCU-CAL™ 50V radiometer is simple to operate and offers repeatable measurement of visible light. The ACCU-CAL 50V can measure visible light energy emitted from lightguides (3 mm, 5 mm, and 8 mm), flood systems, and conveyors.

With a spectral sensitivity from 400 to 470 nm (blue portion of the visible spectrum), the ACCU-CAL 50V measures intensities from 1 mW/cm2 to 40 W/cm2. A specially designed photo sensor assembly protects the photo sensor from the high temperatures sometimes associated with today’s high-intensity spot lamps.

  • Measures range up to 40 W/cm2
  • Sensitive at measuring stray or reflected visible light (as little as 1 mW/cm2)
  • Only one calibration per year
  • Set screw locks lightguide in place
  • PTB and NIST traceable
Download  ACCU-CAL™ 50V Visible Radiometer Intensity Meter Product Bulletin
Download  ACCU-CAL™ 50V Visible Radiometer User Guide
Download  Dymax Light-Curing Equipment Selector Guide

Take advantage of the opportunity to evaluate our light curing systems for two weeks free of charge through our Try-and-Buy program.

ACCU-CAL™ 50V Visible Radiometer Specifications
Spectral Sensitivity 400 to 470 nm
Intensity Range 1 mW/cm2 to 40 W/cm2
Resolution Intensity (1 mW/cm2; to three significant digits)
Dose (1 mJ/cm2)
Calibration Period 12 months
Operating Temperature Ranges Optometer: +5 to +40°C
Measurement Modes Intensity (mW/cm2 and W/cm2)
Peak Intensity (mW/cm2 and W/cm2)
Dose (J/cm2)
Light Sources Lightguides (3 mm, 5 mm, and 8 mm) Floods/Conveyors
Power Supply Two (2) AA batteries
Battery Life 250 hours (automatic shutoff after 1 hour)
Sensor Dimensions Photo Sensor Diameter = 9 mm
Diameter = 37 mm
Thickness = 8 mm
Cable Length = 1 M
Meter Dimensions 120 mm (Length) x 65 mm (Width) x 23 mm (Thickness)
Radiometers & Accessories
Product Part # Description
ACCU-CAL™ 50V for Flood Lamps and Conveyors 40044 Complete radiometer (without lightguide adapters or lightguide simulator*); includes storage/carrying case
ACCU-CAL™ 50V for Spot and Flood Lamps and Conveyors 40043 Complete radiometer with lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*; includes storage/carrying case
Flood to Spot Adapter Kit 39554 Kit includes three lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*
3 mm Lightguide Adapter 39556 Fits 3 mm ID lightguides (5 mm OD)
5 mm Lightguide Adapter 39557 Fits 5 mm ID lightguides (7 mm OD)
8 mm Lightguide Adapter 39558 Fits 8 mm ID lightguides (10 mm OD)
5 mm Lightguide Simulator* 38408 5 mm lightguide simulator* with a standard D connection
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)