UV and Visible Light Curing Adhesives for Needle Bonding and Syringe Needle Assembly |
|
High speed, high volume, needle bonding and syringe needle assembly is possible with Dymax UV and visible light curable adhesives. These products are ISO 10993 approved and bond on demand at room temperature when exposed to UV or visible light. Dymax MD® needle bonding adhesives are solvent-free, single component and fluoresce for in-line testing and inspection. UV and visible light curable medical device adhesives are ideal for automated assembly lines and come in a broad range of product viscosities for design flexibility. Applications include the bonding of cannulas to hubs in various hypodermic and biopsy needles, syringes and winged infusion sets made from multiple plastics, metals, and glass. Dymax MD® needle bonding adhesives are compatible with gamma, EtO and E-Beam sterilization.
|
 |
UV and Visible Light Curing NEEDLE BONDING ADHESIVES Selector Guide |
Click on the product number below for additional information. |
|
| Needle/Syringe Bonder |
Application |
Features |
| New! 1401-M-UR |
High-speed needle bonding; tube assemblies; adheres to stainless steel, PU, PC, PS, ABS, glass, PA, PMMA, and PP |
Solvent free; LED light cure 385 nm or 405 nm; Ultra-Red™ fluorescing; tack-free cure; medium viscosity; single component; ISO 10993 tested »Recommended for use w/ BlueWave® LED Prime UVA |
|
| New! 1402-M |
Needle bonding; tube sets; plastic disposable items; reservoir assemblies; adheres to stainless steel, PC, PU, PS, ABS, PA, PMMA, and PP |
Solvent free; LED light cure 385 nm or 405 nm; blue fluorescing; low viscosity for improved wetting; resists yellowing; fast cure; ISO 10993 tested »Recommended for use w/ BlueWave® LED Prime UVA |
|
| New! 1403-M |
Needle bonding; medical device assembly; disposable applications; adheres to stainless steel, PU, PC, PS, ABS, PA, PMMA, and PP |
Solvent free; LED light cure 385 nm or 405 nm; blue fluorescing; low viscosity for easy dispense; single component; moisture resistant; tack-free cure; ISO 10993 tested »Recommended for use w/ BlueWave® LED Prime UVA |
|
| New! 1404-M-UR |
Needle bonding; medical device assemblies; reservoirs; plastic assemblies; adheres to stainless steel, PU, PC, PS, ABS, PA, PMMA, and PP |
Solvent free; LED light cure 385 nm or 405 nm; Ultra-Red™ fluorescing; higher viscosity; low wicking; one component; ISO 10993 tested »Recommended for use w/ BlueWave® LED Prime UVA |
|
1128-M-VLV
1128A-M
1128A-M-T |
Needle bonding; metal bonding; heat exchanger assembly; adheres to stainless steel, aluminum, nickel titanium, glass, ABS, PA, and PU |
Solvent free; fast UV and visible light cure; secondary heat cure capability; impact resistant; blue fluorescing for in-line inspection under low intensity "black" light (365 nm); ISO 10993 tested |
|
| 1160-M |
Needle bonding; transducer assembly; potting; adheres to PA,
PC,
ABS,
PVC,
PMMA,
stainless steel, and
PS |
Solvent free; fast UV and visible light cure; blue fluorescing for in-line inspection under low intensity "black" light (365 nm); low shrinkage; ISO 10993 tested |
|
| 1161-M |
Tube sets & fittings; reservoirs; needle bonding; adheres to PC, ABS, PVC, PMMA, stainless steel, and PA |
Solvent free; fast UV and visible light cure; blue fluorescing for in-line inspection under low intensity "black" light (365 nm); adhesion to a wide variety of glass,
plastics, and metals; moisture resistant; ISO 10993 tested »Recommended for use w/ BlueWave® LED Prime UVA |
|
1180-M
1180-M-SV04
1180-M-SV05
1180-M-UR
|
Needle bonding; reservoirs; transducer assembly; medical potting applications; adheres to PC, PVC, PU, ABS, and stainless steel |
Solvent free; fast UV and visible light cure; blue fluorescing (UR grades fluoresce Ultra-Red™) for in-line inspection under low-intensity "black" light (365 nm); moisture resistant; ISO 10993 tested |
|
| 1190-M |
Reservoirs; needle bonding; transducer assembly; medical potting applications; adheres to PC, PVC, PU, ABS, and stainless steel |
Solvent free; fast UV and visible light cure; blue fluorescing for in-line inspection under low intensity "black" light (365 nm); recommended for tight tolerance applications; ISO 10993 tested |
|
1193-M
1193-M-SV04
1193-M-SV05
1193M-SV05-UR |
Needle bonding; heat exchanger assembly; adheres to PC, PS, PU, ABS, and stainless steel |
Solvent free; fast UV and visible light cure; blue fluorescing (UR grades fluoresce Ultra-Red™) for in-line inspection under low intensity "black" light (365 nm); recommended for high-speed automation; ISO 10993 tested |
|
|

Max says if you don't see a needle bonding/syringe assembly adhesive that suits your application, call Dymax Applications Engineering for a recommendation. We have a library of over 3,000 adhesive formulations to choose from!
|
|