DYMAX Home
DYMAX Home
Visit our Blog   Follow Us on Twitter   Become a DYMAX Facebook Fan    Connect With Us on LinkedIn    Subscribe to our Light Lines E-Newsletter    Watch Us on YouTube    DYMAX Corporation on Google+
Dymax Worldwide  English  Deutsch  Français  中文  한국어 
SEARCH
 

Home  Products  Medical  Catheter_bonding  





UV and Visible Light Curing
Adhesives for Catheter Bonding

Request an Adhesive Sample!
Consultation Request
Contact Tech Support
DYMAX Corporation - Qmed Qualified Supplier for Medical Device & Diagnostics Industries

The DYMAX "CTH" line of UV and visible light curable catheter bonding adhesives provides reliable cost-saving assembly solutions for catheter manufacturers. These products are ISO 10993 approved and formulated to meet the unique assembly challenges associated with the newest catheter materials. DYMAX light curing adhesives are solvent free and provide excellent adhesion, a high degree of flexibility, and fast cure speeds for consistent, low-stress catheter assembly. In-line inspection is also possible with the patented fluorescing technology included in all featured catheter bonding adhesives. These products are compatible with gamma, EtO and E-Beam sterilization.

Download our MD® Medical Device Adhesives Selector Guide Download our MD® Medical Device Adhesives Selector Guide (492 KB)
Download our We Understand Zero Tolerance For Failure Medical BrochureDownload our We Understand Zero Tolerance For Failure Medical Brochure (1.29 MB)
Improving Production Efficiency Through Light-Curable Medical Device Adhesives Webinar Recording Register to view the "Improving Production Efficiency Through Light-Curable Medical Device Adhesives" webinar recording given by DYMAX in conjunction with Canon Communications

All DYMAX adhesives are RoHS compliant UV and Visible Light Curing CATHETER BONDING ADHESIVES Selector Guide

Click on the product number below for additional information.

Catheter Bonder Application Features
1201-M-SC Catheters; tube sets; reservoirs; adheres to PC, PVC, PU, ABS, PET, and PEBA See-Cure adhesives appear blue when dispensed and become clear when fully cured upon exposure to UV/Visible light. This allows users to know where the adhesive has been applied, as well as if the adhesive is fully cured; solvent free; fast UV and visible light cure; flexible; ISO 10993 tested

»Recommended for use w/ BlueWave® LED Prime UVA

1202-M-SC Catheters; tube sets; metal to plastic assembly; reservoirs; adheres to PMMA, PA, PC, PU, PVC, PET, and stainless steel See-Cure adhesives appear blue when dispensed and become clear when fully cured upon exposure to UV/Visible light. This allows users to know where the adhesive has been applied, as well as if the adhesive is fully cured; solvent free; fast UV and visible light cure;  flexible; ISO 10993 tested

203A-CTH-F Guidewire; lumen sealing; sensor attachment; adheres to stainless steel, aluminum, nickel titanium, PA, and PMMA Solvent free; fast UV and visible light cure; secondary heat cure capability; blue fluorescing for in-line inspection under low-intensity "black" light (365nm); impact resistant; ISO 10993 tested

204-CTH-F Balloon/lumen; hub/lumen; marker band; thermistor potting; adheres to PC, PVC, PU, ABS, PET, and PEBA Solvent free; fast UV and visible light cure; blue fluorescing for in-line inspection under low-intensity "black" light (365nm); flexible; ISO 10993 tested

»Recommended for use w/ BlueWave® LED Prime UVA

208-CTH-F Balloon/lumen; hub/lumen; marker band; tube sets & fittings; adheres to PC, PA, PMMA, PU, PVC, and stainless steel Solvent free; fast UV and visible light cure; blue fluorescing for in-line inspection under low-intensity "black" light (365nm); flexible; ISO 10993 tested

209-CTH Manifold/lumen; hypotube/hub; balloon/lumen; adheres to PC, PVC, ABS, PMMA, PA, and stainless steel Solvent free; fast UV and visible light cure; blue fluorescing for in-line inspection under low-intensity "black" light (365nm); bonds to a variety of plastics and metals; low shrinkage; ISO 10993 tested

»Recommended for use w/ BlueWave® LED Prime UVA

210-CTH Y-Connector assembly; connectors to tubing; balloon bonding; catheter assembly; adheres to PC, PU, PS, PA, ABS, and PVC Solvent free; fast UV and visible light cure; bonds to a wide variety of plastics; moisture resistant; ISO 10993 tested

»Recommended for use w/ BlueWave® LED Prime UVA

New!  211-CTH-SC Y-Connector assembly; connectors to tubing; balloon bonding; catheter assembly; needle bonding; adheres to PC, PU, PS, stainless steel See-Cure adhesives appear blue when dispensed and become clear when fully cured upon exposure to UV/Visible light. This allows users to know where the adhesive has been applied, as well as if the adhesive is fully cured; solvent free; fast UV and visible light cure; bonds to a wide variety of plastics; ideal for >1 W/cm2; ideal for 4-8 mil gaps; ISO 10993 tested

»Recommended for use w/ BlueWave® LED Prime UVA

Catheter Bonding Max

Max says if you don't see a catheter bonding adhesive that suits your application, call DYMAX Applications Engineering for a recommendation. We have a library of over 3,000 adhesive formulations to choose from!


Copyright Notices | Terms of Use | Privacy Statement | Site Index | Impressum |

©2012 DYMAX Corporation | 318 Industrial Lane | Torrington, CT 06790 | ISO 9001 Certified
Phone: (860) 482-1010 | Fax: (860) 496-0608 | E-mail: info@dymax.com