BlueWave® 200 UV Curing Spot Lamp with Intensity Adjustment CE Marked - Available Globally |
|
|
The BlueWave® 200 UV curing spot lamp offers the highest intensity and most user-friendly operation in the industry. The patented intensity adjustment feature allows users to manually adjust intensity. The intensity adjustment feature assists users in validating an appropriate intensity range and maintaining that range during production. Intensity measurement is easily accomplished with the Dymax ACCU-CAL™ 50 radiometer. Scheduled intensity measurements taken during the production process will indicate whether additional intensity adjustments are required. This method of measurement provides the most accurate readings as they are taken through the lightguide in the actual production setting.
 BlueWave® 200 UV Curing Spot Lamp with Intensity Adjustment Shown with Four-Pole Split lightguide
|
|
The BlueWave 200 spot lamp primarily emits UVA and blue visible light (300-450 nm) and is designed for UV curing of adhesives, coatings, and encapsulants. It contains an integral shutter which can be actuated by a foot pedal or PLC making it ideal for both manual and automated processes. A universal power input provides consistent performance at any voltage (90-264V, 47-63 Hz). Dymax also offers a wide range of long-lasting lightguides including liquid/fiber, single/multi-pole and lightguides in various lengths. The BlueWave 200 with manual intensity adjustment is the most versatile, user-friendly and reliable UV curing spot lamp available.
|
| Features |
- Manual intensity adjustment
- Simple to operate and adjust
- >17,000 mW/cm2 initial intensity
- 2,000 hours useful life
- Integral shutter with digital timer
|
- Foot switch or PLC integration
- Wide range of liquid/fiber, single/multi-pole lightguides available
- Fast bulb replacement
- Proprietary "Cool Blue™" filter virtually eliminates lightguide degradation
- Universal power input operates around the globe
|
|
 |
 |
|
Users can manually adjust intensity using either a removable knob or a screwdriver. |
Click to enlarge BlueWave®
overall diagram |
|
| BlueWave® 200 Specifications |
| Initial Intensities |
| Total | (280-450 nm) | 40+ W/cm2 |
| Visible | (400-450 nm) | 17+ W/cm2 |
| UVA1 | (320-395 nm) | 17+ W/cm2 |
| UVB | (280-320 nm) | 7 W/cm2 |
|
| Intensity Adjustment | Manual from 1% to 100% output |
| Power Requirements | 90-264V, 47-63 Hz |
| Power Supplies | Solid-state, 200 Watt |
| Bulb | 200 Watt mercury bulb included; replacement in less than one minute |
| Reflector | Elliptical; glass with dichroic coating to reflect UV and minimize IR |
| Shutter Timer | Digital LCD timer up to 99.99 seconds; manual or timed shutter |
| Shutter Activation | Foot switch or PLC |
| I/O Port | 9 pin D – sub-miniature connector |
| Signals (PLC Integration) | | Inputs: |
Shutter activate, shutter deactivate |
| Outputs: | Lamp on, lamp off, replace lamp Shutter opened, shutter closed, shutter fault |
|
| Cooling | Filtered, dual-fan arrangement; thermally controlled to maintain proper lamp temperature |
| Hour Meter | Digital LCD; lamp hours and bulb hours (re-settable) |
| Overall Dimensions | 12" x 12" x 6.5" (30.5 cm x 30.5 cm x 16.5 cm) |
| Weight | 12 lbs. (5.4 kg) |
| System Warranty | One year from purchase |
| Bulb Warranty | Ignition warranted for 2,000 hours |
| Replacement Bulb Part Number | 38465 |
Part Numbers North American Version (115V Standard Plug)
Asian Version (Type G Power Cord) Unit With No Power Cord | 38905 Request a quote
38605 Request a quote
38903* Request a quote |
1 As measured with a Dymax ACCU-CAL™ 50 Radiometer (320-395 nm). Excessive on/off cycles and improper cooling may affect bulb degradation and therefore no warranty is expressed or implied.
* For European customers, Dymax Europe will add the appropriate power cord
|
|

Max says evaluate UV technology for two weeks FREE! with a Dymax lamp through our Equipment Trial Rental/Lease Program.
|