ACCU-CAL™ 50V Visible Radiometer for use with Visible Light Curing Systems
CE Marked Available Globally |
|
Consistent curing requires periodic monitoring of visible energy intensity or dose. The ACCU-CAL™ 50V radiometer is simple to operate and offers repeatable measurement of visible light. The ACCU-CAL 50V can measure visible light energy emitted from lightguides (3 mm, 5 mm, and 8 mm), flood systems, and conveyors.
With a spectral sensitivity from 395 to 465 nm (blue portion of the visible spectrum), the ACCU-CAL 50V measures intensities from
1 mW/cm2 to 40 W/cm2. A specially designed photo sensor assembly protects the photo sensor from the high temperatures sometimes associated with today’s high-intensity spot lamps.
- Measures range up to 40 W/cm2
- Sensitive at measuring stray or reflected visible light (as little as 1 mW/cm2)
- Only one calibration per year
- Set screw locks lightguide in place
- PTB and NIST traceable
 PN
40044 ACCU-CAL™ 50V for floods and conveyors only. |
 PN 40043 ACCU-CAL™ 50V for spots, floods and conveyors. |
|
| ACCU-CAL™ 50V Visible Radiometer Specifications |
| Spectral Sensitivity | 395 to 465 nm |
| Intensity Range | 1 mW/cm2 to 40 W/cm2 |
| Resolution | Intensity (1 mW/cm2; to three significant digits) Dose (1 mJ/cm2) |
| Calibration Period | 12 months |
| Operating Temperature Ranges | Optometer: +5 to +40°C |
| Measurement Modes | Intensity (mW/cm2 and W/cm2) Peak Intensity (mW/cm2 and W/cm2) Dose (J/cm2) |
| Light Sources | Lightguides (3 mm, 5 mm, and 8 mm) Floods/Conveyors |
| Power Supply | Two (2) AA batteries |
| Battery Life | 250 hours (automatic shutoff after 1 hour) |
| Sensor Dimensions | Photo Sensor Diameter = 9 mm Diameter = 37 mm Thickness = 8 mm Cable Length = 1 M |
| Meter Dimensions | 120 mm (Length) x 65 mm (Width) x 23 mm (Thickness) |
|
| RADIOMETERS and ACCESSORIES |
| Product | Part # | Description |
| ACCU-CAL™ 50V for Flood Lamps and Conveyors | 40044 | Complete radiometer (without lightguide adapters or lightguide simulator*); includes storage/carrying case |
| ACCU-CAL™ 50V for Spot and Flood Lamps and Conveyors | 40043 | Complete radiometer with lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*; includes storage/carrying case |
| Flood to Spot Adapter Kit | 39554 | Kit includes three lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator* |
| 3 mm Lightguide Adapter | 39556 | Fits 3 mm ID lightguides (5 mm OD) |
| 5 mm Lightguide Adapter | 39557 | Fits 5 mm ID lightguides (7 mm OD) |
| 8 mm Lightguide Adapter | 39558 | Fits 8 mm ID lightguides (10 mm OD) |
| 5 mm Lightguide Simulator* | 38408 | 5 mm lightguide simulator* with a standard D connection |
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission) |
|