Typical Curing Intensity of a Measured Square of Light at Specified Distances with a BlueWave 200 Spot Light Curing System
| 38699 Rod Lens Assembly |
| Distance from Surface |
Dimensions of Square on a Side |
Intensity* mW/cm2 |
| 3" (7.62 cm) |
3/4" (1.91 cm) |
1425 |
| 4" (10.16 cm) |
1" (2.54 cm) |
665 |
| 5" (12.70 cm) |
1 1/4" (3.18 cm) |
428 |
| 6" (15.24 cm) |
1 1/2" (3.81 cm) |
309 |
| 7" (17.78 cm) |
1 5/8" (4.13 cm) |
214 |
| 8" (20.32 cm) |
1 3/4" (3.40 cm) |
171 |
| 9" (22.86 cm) |
1 7/8" (4.76 cm) |
133 |
| 10" (25.40 cm) |
2 1/8" (5.40 cm) |
109 |
| 38698 Rod Lens Assembly |
| Distance from Surface |
Dimension of Square on a Side |
Intensity* mW/cm2 |
| 6" (15.24 cm) |
2 3/4" (5.94 cm) |
119 |
| 7" (17.78 cm) |
3 1/4" (8.26 cm) |
86 |
| 8" (20.32 cm) |
3 1/2" (8.89 cm) |
66 |
| 9" (22.86 cm) |
3 3/4" (8.48 cm) |
57 |
| 10" (25.40 cm) |
4 1/4" (10.80 cm) |
46 |
| 11" (27.94 cm) |
4 5/8" (11.75 cm) |
38 |
| 12" (30.48 cm) |
5" (12.70 cm) |
30 |
| *Measured averages over the illuminated area with a DYMAX ACCU-CAL™ 50 Radiometer |
|

BlueWave UV curing spot lamp with 8 mm rod lens. Rod lens stand shown in picture is not available for order from DYMAX. Please contact a laboratory supply company of your choice to order this product
|