2000-PC Series UV Curing Flood Lamp Systems |
|
|
The Dymax 2000-PC Series UV light curing flood lamps offer low-intensity UV curing over a 200mm x 200mm area. Curing in 5-30 seconds is typical using Dymax light curing adhesives. These lamps are available with or without shutters and shielding and are simple to operate. Dymax UV flood lamps can be used as bench-top curing systems or easily integrated into automated assembly systems. These flood lamps offer the industry's most consistent intensity over the 2,000 hour bulb warranty.
 2000-PC UV Flood Lamp shown with Light Shield and ZIP™ Shutter
The 2000-PC UV flood lamp may be fitted with bulbs that produce primarily shortwave UV, primarily longwave UV, or primarily visible light.
|
|
The 2000-PC UV curing flood lamp consists of a power supply, reflector housing and 400 Watt metal halide UV curing bulb.
Accessories can be ordered with or retrofitted to the UV curing lamp after purchase, including shutter assemblies, UV shields and UV flood lamp stands.
|
 2000-PC UV flood lamp shown with no accessories PN 38003 |
| Features |
- Longer Bulb Warranty - these bulbs now come with a 2,000 hour warranty!
- Large 200mm x 200mm curing area
- Typical cure times of 5-30 seconds
- Shutter available that can be actuated by foot pedal or PLC
- Adjustable lamp height
- Bulb options (shortwave and longwave)
- 100% shielding with safety interlock available
|
|
|
| 2000-PC UV Curing Flood Lamp Specifications |
Typical Intensity in the UVA range (320-395 nm1)
Measured at a lamp height of 76mm using a standard metal halide bulb | 75 mW/cm2 |
| Curing Area | 200mm x 200mm |
| Working Distance | 50mm - 150mm |
Dimensions (L x W x H) | Power Supply: 203mm x 318mm x 165mm
Reflector Housing:
267mm x 229mm x 178mm |
| Power Requirements | 90-265V, 50-60 Hz |
Part Numbers:
2000-PC Modular (power supply, reflector housing, bulb) |
38003 Request a quote |
| Bulb Warranty | 2,000 hours |
| Bulb Degradation | < 20% over 2,000 hours |
| Replacement Bulb Part Numbers | 38560 Metal Halide (Standard, UVA, Longwave) 36970 Mercury (UVB, Shortwave) 36658 Visible |
1 Intensity
readings vary widely depending on the make and model of the radiometer. These
intensities were measured with the ACCU-CAL™ 50 radiometer.
|