UVC-5 UV Curing Conveyor System CE Marked - Available in Europe Only |
|
|
The DYMAX UVC-5 conveyor system is designed for curing DYMAX UV adhesives as
well as UV curable inks and coatings. DYMAX conveyors offer very high
intensities for fast UV curing (up to 10 meters per minute). They offer complete shielding from UV light and consistent cure times. These cost-efficient and versatile conveyor systems are perfect for both production and lab environments.
Features
- Intensity up to 400 mW/cm2
- Controlled and consistent cure times
- Adjustable lamp-to-belt distance
- Dependable, heavy-duty conveyor design
- Fully shielded lamp enclosures
- Compact bench-top unit
- Qualified technical support
 UVC-5 UV Curing Conveyor System
The DYMAX UVC-5 Conveyor System is equipped with a 120 mm wide belt. Curing time can be adjusted by changing the belt speed from 1.4 meters to 11 meters per minute continuously. Two bulb types are available: Iron or Mercury. The Mercury system offers a half-capacity mode.
|
| UVC-5 Conveyor System Specifications - Available in Europe Only |
| Maximum UVA Intensity1 |
400 mW/cm2 |
UVA Dose (@ 1 m/min) | 1,800 mJ/cm2 |
| Lamp Type | Focused Beam |
| Number of Lamps | One |
Illuminated Area (one lamp) | Length - 100 mm Width - 120 mm |
| Focal Length | 40 mm |
| Belt Material | 5 mm x 5 mm mesh Teflon coated glass fiber belt |
| Belt Width | 120 mm |
| Belt Speeds | 1 to 10 m/minute |
| Electrical Requirements | 230V, 50 Hz, 5.9A (single phase) |
Overall Dimensions (L x W x H) | 700 mm x 500 mm x 340 mm |
| Load and Unload Length | 90 mm |
| Lamp Height | 20-65 mm |
| Vertical Clearance | Adjustable from 15-60 mm |
| Weight | 28 Kg |
Part Numbers:
UVC-5 with Metal Halide Bulb (std)
UVC-5 with Mercury Bulb
|
Part Number: UVC-5 Request a quote
Part Number: UVC-5/Hg Request a quote
|
Lead Time (Not including shipping) | 2-3 Weeks |
| Bulb Life/Warranty | Typical life - 1,000 hours Warranty - 750 hours |
| Replacement Bulb Part Numbers | UVC-5bulb/Fe Metal Halide UVC-5bulb/Hg Mercury |
1 Intensity
readings vary widely depending on the make and model of the radiometer. These
intensities were measured with the ACCU-CAL™
100 radiometer.
|